Published December 11, 2015 | Version v1
Journal article

Staging of pelvic lymph nodes in patients with prostate cancer: Usefulness of multiple b value SE-EPI diffusion-weighted imaging on a 3.0 T MR system

  • 1. Department of Diagnostic and Interventional Radiology, University of Pisa, Via Paradisa 2, 56124 Pisa (Italy)
  • 2. Department of Urology, University of Pisa, Via Paradisa 2, 56124 Pisa (Italy)

Description

To evaluate the usefulness of diffusion-weighted imaging (DWI) with a multiple b value SE-EPI sequence on a 3.0 T MR scanner for staging of pelvic lymph nodes in patients with prostate cancer candidate to radical prostatectomy and extended pelvic lymph node dissection (PLND). Institutional review board approval was obtained and written informed consent was taken from all enrolled subjects. A series of 26 patients with pathologically proven prostate cancer (high or intermediate risk according to D'Amico risk groups) scheduled for radical prostatectomy and PLND underwent 3 T MRI before surgery. DWI was performed using an axial respiratory-triggered spin-echo echo-planar sequence with multiple b values (500, 800, 1000, 1500 s/mm2) in all diffusion directions. ADC values were calculated by means of dedicated software fitting the curve obtained from the corresponding ADC for each b value. Fitted ADC measurements were performed at the level of proximal and distal external iliac, internal iliac, and obturator nodal stations bilaterally. Lymph node appearance was also assessed in terms of short axis, long-to-short axis ratio, node contour and intranodal heterogeneity of signal intensity. A total of 173 lymph nodes and 104 nodal stations were evaluated on DWI and pathologically analysed. Mean fitted ADC values were 0.79 ± 0.14 × 10−3 mm2/s for metastatic lymph nodes and 1.13 ± 0.29 × 10−3 mm2/s in non-metastatic ones (P < 0.0001). The cut-off for fitted ADC obtained by ROC curve analysis was 0.91 × 10–3 mm2/s. A two-point-level score was assigned for each qualitative parameter, and the mean grading score was 6.09 ± 0.61 for metastastic lymph nodes and 5.42 ± 0.79 for non-metastatic ones, respectively (P = 0.001). Using a score threshold of 4 for morphological, structural, and dimensional MRI analysis and a cut-@@off value of 0.91 × 10–3 mm2/s for fitted ADC measurements of pelvic lymph nodes, per-@@station sensitivity, specificity, PPV, NPV and diagnostic accuracy were 100%, 7.9%, 15.6%, 100% and 21.3%, and 84.6%, 89.5%, 57.9%, 97.1% and 88.8%, respectively. 3.0T DWI with a multiple b value SE-EPI sequence may help distinguish benign from malignant pelvic lymph nodes in patients with prostate cancer

Availability note (English)

Available from http://dx.doi.org/10.1016/j.ejro.2015.11.004; Available from http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4811855

Additional details

Publishing Information

Journal Title
European Journal of Radiology Open
Journal Volume
3
Journal Page Range
p. 16-21
ISSN
2352-0477

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
47117599
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
ANALOG-TO-DIGITAL CONVERTERS; BIOMEDICAL RADIOGRAPHY; COMPUTER CODES; IMAGES; LYMPH NODES; NEOPLASMS; NMR IMAGING; PATIENTS; PROSTATE; SPIN ECHO
Descriptors DEC
BODY; DIAGNOSTIC TECHNIQUES; DISEASES; ELECTRONIC EQUIPMENT; EQUIPMENT; GLANDS; LYMPHATIC SYSTEM; MALE GENITALS; MEDICINE; NUCLEAR MEDICINE; ORGANS; RADIOLOGY

Optional Information

Copyright
Copyright (c) 2015 The Authors
Notes
PMCID: PMC4811855; PMID: 27069974; PUBLISHER-ID: S2352-0477(15)30010-1; OAI: oai:pubmedcentral.nih.gov:4811855; This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).