Published February 1981 | Version v1
Journal article

Hepatic imaging: a comparison of Tc-99m-sulfur colloid and PIPIDA in the detection of defects

Description

A prospective investigation comparing Tc-99m-PIPIDA with Tc-99m-sulfur colloid in the detection of defects of the liver was carried out in 30 volunteers. By acquiring images of 1 million counts from 5 to 10 minutes postinjection, high quality hepatic images could be obtained with PIPIDA. Separate interpretations by three nuclear physicians yielded similar results between paired PIPIDA and sulfur colloid studies (KAV = 0.95 +- .09, P less than 0.001). Early multiview imaging of the liver in the course of hepatobiliary evaluation with PIPIDA may yield valuable information relative to the presence of lesions

Additional details

Publishing Information

Journal Title
Clin. Nucl. Med.
Journal Volume
6
Journal Issue
2
Series
Clin. Nucl. Med.
Journal Page Range
53-56
ISSN
0363-9762