Published December 2015 | Version v1
Journal article

A study of usefulness for the plan based on only MRI using ViewRay MRIdian system

  • 1. Dept. of Radiation Oncology, Seoul National University Hospital, Seoul (Korea, Republic of)

Description

By comparing a CT fusion plan based on MRI with a plan based on only MRI without CT, we intended to study usefulness of a plan based on only MRI. And furthermore, we intended to realize a realtime MR-IGRT by MRI image without CT scan during the course of simulation, treatment planning, and radiation treatment. BBB CT (Brilliance Big Bore CT, 16slice, Philips), Viewray MRIdian system (Viewray, USA) were used for CT and MR simulation and Treatment plan of 11 patients (1 Head and Neck, 5 Breast, 1 Lung, 3 Liver, 1 Prostate). When scanning for treatment, Free Breathing was enacted for Head and Neck, Breast, Prostate and Inhalation Breathing Holding for Lung and Liver. Considering the difference of size between CT and Viewray, the patient's position and devices were in the same condition. Using Viewray MRIdian system, two treatment plans were established. The one was CT fusion treatment plan based on MR image. Another was MR treatment plan including electron density that [ICRU 46] recommend for Lung, Air and Bone. For Head and Neck, Breast and Prostate, IMRT was established and for Lung and Liver, Gating treatment plan was established. PTV's Homogeneity Index(HI) and Conformity Index(CI) were use to estimate the treatment plan. And DVH and dose difference of each PTV and OAR were compared to estimate the treatment plan. Between the two treatment plan, each difference of PTV's HI value is 0.089% (Head and Neck), 0.26% (Breast), 0.67% (Lung), 0.2% (Liver), 0.4% (Prostate) and in case of CI, 0.043% (Head and Neck), 0.84% (Breast), 0.68% (Lung), 0.46% (Liver), 0.3% (Prostate). As showed above, it is on Head and Neck that HI and CI's difference value is smallest. Each difference of average dose on PTV is 0.07 Gy (Head and Neck), 0.29 Gy (Breast), 0.18 Gy (Lung), 0.3 Gy (Liver), 0.18 Gy (Prostate). And by percentage, it is 0.06% (Head and Neck), 0.7% (Breast), 0.29% (Lung), 0.69% (Liver), 0.44% (Prostate). Likewise, All is under 1%. In Head and Neck, average dose difference of each OAR is 0.01-0.12 Gy, 0.04-0.06 Gy in Breast, 0.01-0.21 Gy in Lung, 0.06-0.27 Gy in Liver and 0.02-0.23 Gy in Prostate. PTV's HI, CI dose difference on the Treatment plan using MR image is under 1% and OAR's dose difference is maximum 0.89 Gy as heterogeneous tissue increases when comparing with that fused CT image. Besides, It characterizes excellent contrast in soft tissue. So, radiation therapy using only MR image without CT scan is useful in the part like Head and Neck, partial breast and prostate cancer which has a little difference of heterogeneity

Additional details

Publishing Information

Journal Title
Journal of the Korean Society for Radiotherapeutic Technology
Journal Volume
27
Journal Issue
2
Series
8 refs, 8 figs, 6 tabs
Journal Page Range
p. 131-143
ISSN
1598-8449

INIS

Country of Publication
Korea, Republic of
Country of Input or Organization
Korea, Republic of
INIS RN
47086861
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
COMPUTERIZED TOMOGRAPHY; MAMMARY GLANDS; NECK; NMR IMAGING; PATIENTS; RADIOTHERAPY; USES
Descriptors DEC
BODY; DIAGNOSTIC TECHNIQUES; GLANDS; MEDICINE; NUCLEAR MEDICINE; ORGANS; RADIOLOGY; THERAPY; TOMOGRAPHY