Published 2006 | Version v1
Journal article

Monte Carlo Dose Calculation for Breast Radiotherapy using 60 CO Gamma Rays

  • 1. physics Dep., faculty of Sciences, Zagazig, Uin., Zagazig (Egypt)
  • 2. Atomic Energy Authority, Cairo (Egypt)

Description

The present study aims to/assess radiation dose received by the target tumor cells and non-target organs during breast radiotherapy. The human body with its details, was modeled using three dimensional Monte Carlo Nuclear Particles Code (MCNP-4B). The dose distribution from ''6''0Co γ-rays, with average energy 1.25 MeV, in two fields in human theoretical model was calculated at selected points using the same code. Monte Carlo computer calculations of the photon spectra and the ratios of doses at the surfaces and in some of the internal organs of the model were also performed. In order to validate the calculated data, dose distribution at the same selected points were measured during a real radiotherapy practice using ARP phantom and TLD. Moreover, depth dose distribution was established by modeling water phantom with capacity 80 cm''3 and measured by ion chamber 0.125. Both measured and calculated data were compared. The comparison showed that the calculated and the measured data have the same behavior in different organs. The correlation coefficient of both sets of data (R) was found to be 0.9126. The comparison between calculated and measured depth dose gives fair agreement

Additional details

Publishing Information

Journal Title
Journal of Nuclear and Radiation Physics
Journal Volume
1
Journal Issue
1
Journal Page Range
p. 61-72
ISSN
1687-420X