Energy deposition and its effects on the E+ capture section at Sector 20
Description
The temperature profile and resulting stresses and strains of the capture section (positron source accelerator section) at Sector 20 were investigated. The Electron-Gamma Shower program, Version 4 (EGS4) was used to determine energy deposition. For a 31.68 kW, 33 GeV electron beam, the rate of energy deposition in the first accelerator disk downstream from the 90/10 tantalum-tungsten positron target was determined to be 0.56 kW. The calculated resulting temperature difference from the inner disk diameter to the outer disk diameter is 49.40F. The inner diameter could then reach a temperature of 169.50F. The maximum stress produced in this first disk would be a compressive stress of 4374 psi, also at the inner diameter
Availability note (English)
MF available from INIS under the Report Number; Available from NTIS, PC A02/MF A01; 1 as DE85010964.Files
16077992.pdf
Files
(344.6 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:6e2156a23da0297ca66cf23f2be67573
|
344.6 kB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- 19 p.
- Report number
- SLAC-CN--294
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 16077992
- Subject category
- S43: PARTICLE ACCELERATORS;
- Descriptors DEI
- BEAM DUMPS; COMPUTERIZED SIMULATION; ELECTRON BEAMS; ENERGY DEPOSITION; ENERGY LOSSES; HEAT TRANSFER; POSITRON SOURCES; STANFORD LINEAR COLLIDER
- Descriptors DEC
- ACCELERATORS; BEAMS; ENERGY TRANSFER; LEPTON BEAMS; LINEAR ACCELERATORS; PARTICLE BEAMS; PARTICLE SOURCES; RADIATION SOURCES; SIMULATION