Published April 1998 | Version v1
Journal article

Preparation of ion-implanted and sub-monolayer 111In-tracer layers for perturbed angular correlation analysis

  • 1. Goettingen Univ. (Germany). 2. Physikalisches Inst.

Description

Some 1012 radioactive 111In-tracer atoms are routinely implanted at 400 keV into different samples to perform perturbed angular correlation (PAC) measurements. The experimental details and the tricks used during the preparation and implantation are summarized. As an alternative to ion-implantation, a method to deposit submonolayer 111In-tracer films into metallic multilayers is described. The different applications and benefits of both techniques are compared. (orig.)

Additional details

Publishing Information

Journal Title
Nuclear Instruments and Methods in Physics Research. Section B, Beam Interactions with Materials and Atoms
Journal Volume
139
Journal Issue
1-4
Journal Page Range
p. 306-312
ISSN
0168-583X
CODEN
NIMBEU

Conference

Title
5. European conference on accelerators in applied research and technology (ECAART-5) and industrial exhibition
Dates
26-30 Aug 1997
Place
Eindhoven (Netherlands)

Optional Information

Notes
15 refs.