Published 1984 | Version v1
Report Open

Modeling a forced to natural convection boiling test with the program LOOP-W

Description

Extensive testing has been conducted in the Simulant Boiling Flow Visualization (SBFV) loop in which water is boiled in a vertical transparent tube by circulating hot glycerine in an annulus surrounding the tube. Tests ranged from nonboiling forced convection to oscillatory boiling natural convection. The program LOOP-W has been developed to analyze these tests. This program is a multi-leg, one-dimensional, two-phase equilibrium model with slip between the phases. In this study, a specific test, performed at low power where non-boiling forced convection was changed to boiling natural convection and then to non-boiling again, has been modeled with the program LOOP-W

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS, PC A02/MF A01; 1 as DE84014256.

Files

16011059.pdf

Files (133.7 kB)

Name Size Download all
md5:9bded10e39194a5cd42f008835778ee2
133.7 kB Preview Download

Additional details

Additional titles

Augmented title (English)
LMFBR

Publishing Information

Imprint Pagination
8 p.
Report number
CONF-840614--67

Conference

Title
Annual meeting of the American Nuclear Society.
Dates
3-8 Jun 1984.
Place
New Orleans, LA (USA).