Published 2006 | Version v1
Book

Development and operational experience of traveling in core probe drive for flux scan of 540 MWe PHWR of Tarapur

  • 1. R and D -Nuclear System, C and I - PC-1, Nuclear Power Corporation, Mumbai (India)

Description

TAPP-3 and 4 reactors use large number of Self Powered Neutron Detectors (SPNDs) for Neutronic lower measurement and control. To perform in-situ calibration of these detectors in select locations and to validate the reactor physics codes which predict flux at various points in the core, traveling in-core probes (TIP) are required. The TIP assembly consists of a miniature neutron sensitive detector. The detector is driven in and out of core using a mechanism which facilitates positioning of the detector anywhere inside a vertical tube (Central carrier tube of any of the six select Vertical Flux Units) in the core. TIP is driven through retractable feed mechanism for a stroke of 13 m. This paper describes the developmental efforts and the operational feedback of the retractable feed mechanism for the stroke of 13 m used at TAPP 3 and 4 reactor. (author)

Part of:
Proceedings of national conference on operating experience of nuclear reactors and power plants: book of preprints

Additional details

Publishing Information

Publisher
Prime Time Education
Imprint Place
Mumbai (India)
ISBN
81-8372-028-5
Imprint Title
Proceedings of national conference on operating experience of nuclear reactors and power plants: book of preprints
Imprint Pagination
1313 p.
Journal Page Range
p. 919-925

Conference

Title
operating experience of nuclear reactors and power plants; NRT-3: 3. nuclear reactor technology
Acronym
OPENUPP-2006
Dates
13-15 Nov 2006
Place
Mumbai (India)

Optional Information

Notes
5 figs.