The flow measurement technology using ultrasonic has been developed rapidly enough to substitute the conventional flow measuring technology such as venturi, flow nozzle and orifice. As one of Projects supported by MOCIE (Ministry of Commerce, Industry and Energy), the feedwater flow measurement technology using ultrasonic flow meter (UFM) is developed to recover the electrical power loss, which is considered to be attributed to the overestimated feedwater flow rate due to a anomaly in the venturi throat, known as the venture fouling. In this paper, some key developments of the project are presented to show the applicability of clamp-on transit-time UFM for feedwater flow measurement in Nuclear Power Plant

Part of:
Proceedings of the KNS autumn meeting

Additional details

Publishing Information

Publisher
KNS
Imprint Place
Taejon (Korea, Republic of)
Imprint Title
Proceedings of the KNS autumn meeting
Imprint Pagination
[1 CD-ROM]
Journal Page Range
[2 p.]

Conference

Title
2005 autumn meeting of the KNS
Dates
27-28 Oct 2005
Place
Busan (Korea, Republic of)

INIS

Country of Publication
Korea, Republic of
Country of Input or Organization
Korea, Republic of
INIS RN
37072408
Subject category
S22: GENERAL STUDIES OF NUCLEAR REACTORS;
Resource subtype / Literary indicator
Conference, Non-conventional Literature
Descriptors DEI
ELECTRIC POWER; FEEDWATER; FLOW RATE; NUCLEAR POWER PLANTS; PERFORMANCE; VERIFICATION
Descriptors DEC
HYDROGEN COMPOUNDS; NUCLEAR FACILITIES; OXYGEN COMPOUNDS; POWER; POWER PLANTS; THERMAL POWER PLANTS; WATER

Optional Information

Notes
3 refs, 3 figs