Published 2005
| Version v1
Miscellaneous
Feedwater Flow Measurement Using Transit-time Ultrasonic Flow Meter in Nuclear Power Plant
- 1. Korea Power Engineering Company, Inc., Taejon (Korea, Republic of)
Description
The flow measurement technology using ultrasonic has been developed rapidly enough to substitute the conventional flow measuring technology such as venturi, flow nozzle and orifice. As one of Projects supported by MOCIE (Ministry of Commerce, Industry and Energy), the feedwater flow measurement technology using ultrasonic flow meter (UFM) is developed to recover the electrical power loss, which is considered to be attributed to the overestimated feedwater flow rate due to a anomaly in the venturi throat, known as the venture fouling. In this paper, some key developments of the project are presented to show the applicability of clamp-on transit-time UFM for feedwater flow measurement in Nuclear Power Plant
Additional details
Publishing Information
- Publisher
- KNS
- Imprint Place
- Taejon (Korea, Republic of)
- Imprint Title
- Proceedings of the KNS autumn meeting
- Imprint Pagination
- [1 CD-ROM]
- Journal Page Range
- [2 p.]
Conference
- Title
- 2005 autumn meeting of the KNS
- Dates
- 27-28 Oct 2005
- Place
- Busan (Korea, Republic of)
INIS
- Country of Publication
- Korea, Republic of
- Country of Input or Organization
- Korea, Republic of
- INIS RN
- 37072408
- Subject category
- S22: GENERAL STUDIES OF NUCLEAR REACTORS;
- Resource subtype / Literary indicator
- Conference, Non-conventional Literature
- Descriptors DEI
- ELECTRIC POWER; FEEDWATER; FLOW RATE; NUCLEAR POWER PLANTS; PERFORMANCE; VERIFICATION
- Descriptors DEC
- HYDROGEN COMPOUNDS; NUCLEAR FACILITIES; OXYGEN COMPOUNDS; POWER; POWER PLANTS; THERMAL POWER PLANTS; WATER
Optional Information
- Notes
- 3 refs, 3 figs