Published 1996 | Version v1
Book

On-power verification of the dynamic response of self-powered in-core detectors

  • 1. Serdula Systems Ltd., Deep River, ON (Canada)
  • 2. Hydro-Quebec (Canada)

Description

Self-powered in-core detectors are used for on-line safety and regulation purposes in CANDU reactors. Such applications require use of detectors whose response is primarily prompt to changes in flux. In-service verification of the detectors' response is required to ensure significant degradation in performance has not occurred during long-term operation. Changes in the detector characteristics occur due to nuclear interactions and failures. Present verification requires significant station resources and disrupts power production. Use of the 'noise' in the detector signal is being investigated as an alternative to assess the dynamic response of the detectors during long-term operation. Measurements of reference 'signatures' were obtained from replacement shutdown system detectors. Results show 'noise' measurements are a promising alternative to the current verification method. Identification of changes in the detector response function assist in accurate diagnosis and prognosis of changes in detector signals due to process changes. (author)

Part of:
SMORN VII

Additional details

Publishing Information

Publisher
Organisation for Economic Co-Operation and Development.
Imprint Place
Paris (France)
Imprint Title
SMORN VII
Imprint Pagination
(v.2) 578 p.
Journal Page Range
p. 392-399.

Conference

Title
Symposium on nuclear reactor surveillance and diagnostics.
Dates
19-23 Jun 1995.
Place
Avignon (France).

Optional Information

Notes
4 refs.