Published July 1983 | Version v1
Journal article

Radionuclide kinetics in MIRD dose calculations

Creators

  • 1. Univ. of Utah, Salt Lake City

Description

A recent case report is reviewed and an alternative model for the radionuclide kinetics is presented; it estimates in an absorbed dose differing by a factor of two from the published calculation. Both models are consistent with observed data. Within a compartment model, one may choose to monitor a compartment of interest directly, or to monitor another compartment and (indirectly) solve for the activity in the compartment of interest. Advantages and disadvantages are reviewed

Additional details

Publishing Information

Journal Title
J. Nucl. Med.
Journal Volume
24
Journal Issue
7
Series
J. Nucl. Med.
Journal Page Range
621-624
ISSN
0022-3123

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
15001815
Subject category
S63: RADIATION, THERMAL, AND OTHER ENVIRONMENTAL POLLUTANT EFFECTS ON LIVING ORGANISMS AND BIOLOGICAL MATERIALS;
Descriptors DEI
ALGORITHMS; COMPARTMENTS; MATHEMATICAL MODELS; RADIATION DOSES; RADIONUCLIDE KINETICS
Descriptors DEC
KINETICS