Published February 1986 | Version v1
Report

Surry steam generator - examination and evaluation

  • 1. Pacific Northwest Lab., Richland, WA

Description

This report summarizes research conducted during the fourth year of the five year Steam Generator Group Project. During this period the project conducted numerous nondestructive examination (NDE) round robin inspections of the original Surry 2A steam generator. They included data acquisition/analysis and analysis-only round robins using multifrequency bobbin coil eddy current tests. In addition, the generator was nondestructively examined by alternate or advanced techniques including ultrasonics, optical fiber, profilometry and special eddy current instrumentation. The round robin interpretation data were compared. To validate the NDE results and for tube integrity testing, a selection of tubing samples, determined to be representative of the generator, was designated for removal. Initial sample removals from the generator included three sections of tube sheet, two sections of support plate and encompassed tubes, and a number of straight and U-bend tubing sections. Metallographic examination of these sections was initiated. Details of significant results are presented in the paper

Additional details

Publishing Information

Imprint Title
Thirteenth Water Reactor Safety Research Information Meeting. Volume 2
Journal Page Range
p. 409-430.
Report number
NUREG/CP--0072-Vol.2

Conference

Title
13. water reactor safety research information meeting.
Dates
22-25 Oct 1985.
Place
Gaithersburg, MD (USA).