Effect of heterogeneity correction on dosimetric parameters of radiotherapy planning for thoracic esophageal cancer

  • 1. Division of Radiation Oncology, Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan)
  • 2. Radiology Department, Kobe University Hospital, Kobe, Hyogo (Japan)

Description

The present study aimed to investigate the effect of heterogeneity correction (HC) on dosimetric parameters in 3-dimensional conformal radiotherapy planning for patients with thoracic esophageal cancer. We retrospectively analyzed 20 patients. Two treatment plans were generated for each patient using a superposition algorithm on the Xio radiotherapy planning system. The first plan was calculated without HC. The second was a new plan calculated with HC, using identical beam geometries and maintaining the same number of monitor units as the first. With regard to the planning target volume (PTV), the overall mean differences in the prescription dose, maximum dose, mean dose, and dose that covers 95% of the PTV between the first and second plans were 1.10 Gy (1.8%), 1.35 Gy (2.2%), 1.10 Gy (1.9%), and 0.56 Gy (1.0%), respectively. With regard to parameters related to the organs at risk (OARs), the mean differences in the absolute percentages of lung volume receiving greater than 5, 10, 20, and 30 Gy (lung V5, V10, V20, and V30) between the first and second plans were 7.1%, 2.7%, 0.4%, and 0.5%, respectively. These results suggest that HC might have a more pronounced effect on the percentages of lung volume receiving lower doses (e.g., V5 and V10) than on the dosimetric parameters related to the PTV and other OARs

Availability note (English)

Available from http://dx.doi.org/10.1016/j.meddos.2013.09.001

Additional details

Identifiers

DOI
10.1016/j.meddos.2013.09.001;
PII
S0958-3947(13)00099-X;

Publishing Information

Journal Title
Medical Dosimetry
Journal Volume
39
Journal Issue
1
Journal Page Range
p. 31-33
ISSN
0958-3947

INIS

Country of Publication
United States
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
45089195
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
ALGORITHMS; CORRECTIONS; ESOPHAGUS; LUNGS; NEOPLASMS; PATIENTS; PLANNING; RADIATION DOSES; RADIOTHERAPY
Descriptors DEC
BODY; DIGESTIVE SYSTEM; DISEASES; DOSES; MATHEMATICAL LOGIC; MEDICINE; NUCLEAR MEDICINE; ORGANS; RADIOLOGY; RESPIRATORY SYSTEM; THERAPY

Optional Information

Copyright