It is shown that today the turbo generators with hydrogen-water cooling system is most unreliable technical equipment of Ukrainian nuclear power plants. On the one hand, hydrogen has several advantages over other coolers; on the other hand, the presence of hydrogen in the turbo generators systems carries the danger of engine rooms of power plants. It is also shown that the water and oxygen are main hazardous impurities in hydrogen, and zone of generator shaft compaction is the most responsible zone with high concentration of water. From the analysis was found that increasing of hydrogen purity reduces the mechanical losses and the change in total losses depending on the hydrogen purity has a linear nature. For example, with an increase the hydrogen purity from 0,1203 to 0,09 the loss in turbo generator rotor can be reduced by nearly 500 kW, which is about 25 % at a pressure of 0,5 MPa. The possibility of using metal hydrides to ensure purity, purification and hydrogen sorption was looked. The most practical value is for such hydrides as LaNi5Hx, FeTiHx, ZrNiHx. The main advantage the metal hydrides method of purification is a significant reduction in the number of purification stages. It was shown that the use of a thermoelectric gas dryer will reduce the total consumption of technological gases, that are removed from nuclear power plants, by 2,3 - 2,4 times due to a decrease in 5,0 - 6,0 times their absolute humidity, and decrease by 5, 0 times the activity of gases due to an increase in their exposure time in the decrease activity installation. All this suggests that the creation a hydrogen humidity monitoring system in the exploited turbo generator will solve the problem of objective control of hydrogen purity with further computerization and accumulation the information. Using a drainage or purification system of hydrogen, reducing the temperature and humidity of the cooling gas, can increase the reliability of operation the turbo generators and significantly expand the range of admissible electrical and thermal loads.

Additional details

Additional titles

Original title (Ukrainian)
Vpliv vologostyi ta chistoti vodnyu na nadyijnyist' potuzhnikh elektrichnikh mashin

Publishing Information

Journal Title
Problemi Bezpeki Atomnikh Elektrostantsyij yi Chornobilya
Journal Volume
29
Journal Page Range
p. 14-21