Published 2004 | Version v1
Miscellaneous

Improvement of the exponential experiment system for the automatical and accurate measurement of the exponential decay constant

  • 1. KAERI, Taejon (Korea, Republic of)

Description

The previous exponential experiment system has been improved for the automatical and accurate axial movement of the neutron source and detector with attaching the automatical control system which consists of a Programmable Logical Controller(PLC) and a stepping motor set. The automatic control program which controls MCA and PLC consistently has been also developed on the basis of GENIE 2000 library. The exponential experiments have been carried out for Kori 1 unit spent fuel assemblies, C14, J14 and G23, and Kori 2 unit spent fuel assembly, J44, using the improved systematical measurement system. As the results, the average exponential decay constants for 4 assemblies are determined to be 0.1302, 0.1267, 0.1247, and 0.1210, respectively, with the application of poisson regression

Part of:
Proceedings of the Korean Radioactive Waste Society Spring, 2004

Additional details

Publishing Information

Publisher
KRWS
Imprint Place
Taejon (Korea, Republic of)
Imprint Title
Proceedings of the Korean Radioactive Waste Society Spring, 2004
Imprint Pagination
438 p.
Journal Page Range
p. 292-303

Conference

Title
2004 Spring Meeting of the Korean Radioactive Waste Society
Dates
24-25 Jun 2004
Place
Seoul (Korea, Republic of)

Optional Information

Notes
14 refs, 6 figs, 4 tabs