Possibility of revitalization of control system of steam turbine 210 MW LMZ

  • 1. ALSTOM, Karlovats (Croatia)

Description

It is a one-shaft, three casing, condensing turbine, type K-210-130. A rigid coupling connects it directly to the electric energy generator. There is one intermediate superheat of steam and seven non regulated blending s for regenerative condensate heating. A considerate number of such turbines have been used on the territory of the Eastern Europe. There are two blocks installed in TP Sisak, Croatia. There is a survey of the existing control system of turbine, power 210 MW. It points out and describes problems appearing during exploitation. Technical solutions according to complexity of realization have been described. It gives an overview of minimum range of modification with utilization of the existing oil system and maximum range by adding separate high pressure oil system with new solution for performing segments. (Author)

Additional details

Additional titles

Original title (Macedonian)
Mozhnosti za revitalizatsija na regulatsioniot sistem na parnata turbina 210 MW LMZ

Publishing Information

Journal Title
Energetika
Journal Volume
15
Journal Issue
58
Journal Page Range
p. 11-13, 15-16
ISSN
1409-6048

Optional Information

Notes
8 ref., 3 fig., 2 ills.