Published February 1988 | Version v1
Journal article

Results of silicon strip detector readout using a CMOS low power microplex (MX1)

  • 1. Rutherford Appleton Lab., Chilton, Oxon (UK)

Description

A system for reading out silicon strip detectors has been fabricated on a CMOS integrated circuit. The chip consists of an array of 128 amplifiers with a single multiplexed output. These chips have been bonded to a 256 channel silicon strip detector. Results are reported on the electrical parameters of the chips and on data taken during exposure of the instrumented detectors to minimum ionising beta particles. The radiation tolerance of the device has been investigated

Additional details

Publishing Information

Journal Title
IEEE Trans. Nucl. Sci.
Journal Volume
35
Journal Issue
1
Series
IEEE Trans. Nucl. Sci.
Journal Page Range
176-180
ISSN
0018-9499
CODEN
IETNA

Conference

Title
34. nuclear science symposium and 19. nuclear power systems symposium.
Dates
21-23 Oct 1987.
Place
San Francisco, CA (USA).

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
19092986
Subject category
S42: ENGINEERING; S43: PARTICLE ACCELERATORS;
Resource subtype / Literary indicator
Conference
Descriptors DEI
ACCELERATORS; AMPLIFIERS; FABRICATION; INTEGRATED CIRCUITS; MULTIPLEXERS
Descriptors DEC
ELECTRONIC CIRCUITS; ELECTRONIC EQUIPMENT; EQUIPMENT

Optional Information

Secondary number(s)
CONF-871006--.