The effect of focal spot size on the spatial resolution of variable resolution X-ray CT scanner
Creators
- 1. Shahid Beheshti University, Radiation Medicine Department, Tehran (Iran, Islamic Republic of)
Description
A variable resolution X-ray CT scanner provides a great increase In the spatial resolution. In variable resolution X-ray CT scanners, the spatial resolution of the system and its field of view can be changed according to the object size. One of the main factors that limit the spatial resolution of variable resolution X-ray CT scanner is the effect of the X-ray focal spot. Materials and Methods: A theoretical study of the effect of X-ray focal spot on the spatial resolution of variable resolution X-ray CT is presented in this paper. In this study, we used the parameters of an actual variable resolution X-ray CT scanner. By using the relevant equations, the effects of foal spot sizes of 0.6 and 0.1 mm were calculated on spatial resolution of the system at various opening half angles. Results: Focal spot size of 0.6 mm had no significant effect on spatial resolution of the system for opening half angles of above 14degree. Even focal spot sizes of larger than 0.6 mm could not affect the spatial resolution of the system. For opening half angles of below 14degree, foal spot size of 0.6 mm limited the spatial resolution of the system to 5.7 cycle/mm and caused great spatial resolution non-uniformity along the detector length. Conclusion: By focal spot size of 0.1 mm, the spatial resolution varied as a function of the opening half angle and increased to more than 30 cycle/mm. Additionally, focal spot size of 0.1 mm minimized the spatial resolution non-uniformity along the detector length.
Availability note (English)
Available from Atomic Energy Organization of IranAdditional details
Publishing Information
- Journal Title
- Iranian Journal of Radiation Research (Print)
- Journal Volume
- 8
- Journal Issue
- no.1
- Journal Page Range
- p. 37-43
- ISSN
- 1728-4554
INIS
- Country of Publication
- Iran, Islamic Republic of
- Country of Input or Organization
- Iran, Islamic Republic of
- INIS RN
- 42044738
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- CAT SCANNING; COMPUTER CODES; IMAGE SCANNERS; SPATIAL RESOLUTION; X RADIATION
- Descriptors DEC
- COMPUTERIZED TOMOGRAPHY; DIAGNOSTIC TECHNIQUES; ELECTROMAGNETIC RADIATION; IONIZING RADIATIONS; RADIATIONS; RESOLUTION; TOMOGRAPHY