Published December 15, 1986 | Version v1
Journal article

Direct measurement of the energy spectrum of an intense proton beam

  • 1. Sandia National Laboratories, Albuquerque, New Mexico 87185

Description

A time-resolved magnetic spectrograph was used to measure the energy spectrum of an intense (0.7 TW/cm2) proton beam. A thin gold foil placed at the focus of an ion-diode Rutherford-scattered protons by 900 into the spectrograph, reducing the beam intensity to a level suitable for magnetic analysis. The scattered protons were collimated and then deflected in a samarium-cobalt permanent magnet. The deflected protons were recorded simultaneously on CR-39 and eight p-i-n diodes. A Monte Carlo computer code was used to calculate the sensitivity and resolution of the spectrograph. Data taken on the Proto I accelerator shows a 150--250-keV-wide proton-energy spectrum at each instant in time

Additional details

Publishing Information

Journal Title
J. Appl. Phys.
Journal Volume
60
Journal Issue
12
Series
J. Appl. Phys.
Journal Page Range
4059-4063
ISSN
0021-8979
CODEN
JAPIA