Published June 1989
| Version v1
Report
A dual system for the stabilisation of the vertical plasma position of the Jet experiment
- 1. Commission of the European Communities, Abingdon (UK). JET Joint Undertaking
- 2. Padua Univ. (Italy)
Description
The vertical position of the JET plasma is unstable without feedback stabilisation. The growth rate can reach 200s-1 for strongly elongated plasmas (b/a ≅ 2). A failure of the stabilisation at large plasma current (7MA) can cause damage to the vessel due to large vertical forces. A dual system which continues the stabilisation even in case of faults in the measurement system or in the conditioning electronics is needed for high reliability. A significant simplification in the control was also achieved by avoiding magnetic signals integration
Additional details
Publishing Information
- Imprint Title
- Jet Joint Undertaking. Vol. 2
- Imprint Pagination
- 648 p.
- Journal Page Range
- p. A350-A354.
- Report number
- EUR--12323
Conference
- Title
- 15. Symposium on Fusion Technology (SOFT).
- Dates
- 19-23 Sep 1988.
- Place
- Utrecht (Netherlands).
INIS
- Country of Publication
- European Commission (EC), Brussels (Belgium)
- Country of Input or Organization
- European Commission (EC), Brussels (Belgium)
- INIS RN
- 22010751
- Subject category
- S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- AMPLIFIERS; CONTROL SYSTEMS; ELECTRIC CURRENTS; JET TOKAMAK; PLASMA CONFINEMENT; PLASMA INSTABILITY; STABILITY
- Descriptors DEC
- CLOSED PLASMA DEVICES; CONFINEMENT; CURRENTS; EQUIPMENT; INSTABILITY; THERMONUCLEAR DEVICES; TOKAMAK DEVICES
Optional Information
- Secondary number(s)
- EUR-JET-PR--6.