Published June 1989 | Version v1
Report

A dual system for the stabilisation of the vertical plasma position of the Jet experiment

  • 1. Commission of the European Communities, Abingdon (UK). JET Joint Undertaking
  • 2. Padua Univ. (Italy)

Description

The vertical position of the JET plasma is unstable without feedback stabilisation. The growth rate can reach 200s-1 for strongly elongated plasmas (b/a ≅ 2). A failure of the stabilisation at large plasma current (7MA) can cause damage to the vessel due to large vertical forces. A dual system which continues the stabilisation even in case of faults in the measurement system or in the conditioning electronics is needed for high reliability. A significant simplification in the control was also achieved by avoiding magnetic signals integration

Part of:
Jet Joint Undertaking. Vol. 2

Additional details

Publishing Information

Imprint Title
Jet Joint Undertaking. Vol. 2
Imprint Pagination
648 p.
Journal Page Range
p. A350-A354.
Report number
EUR--12323

Conference

Title
15. Symposium on Fusion Technology (SOFT).
Dates
19-23 Sep 1988.
Place
Utrecht (Netherlands).

INIS

Country of Publication
European Commission (EC), Brussels (Belgium)
Country of Input or Organization
European Commission (EC), Brussels (Belgium)
INIS RN
22010751
Subject category
S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
AMPLIFIERS; CONTROL SYSTEMS; ELECTRIC CURRENTS; JET TOKAMAK; PLASMA CONFINEMENT; PLASMA INSTABILITY; STABILITY
Descriptors DEC
CLOSED PLASMA DEVICES; CONFINEMENT; CURRENTS; EQUIPMENT; INSTABILITY; THERMONUCLEAR DEVICES; TOKAMAK DEVICES

Optional Information

Secondary number(s)
EUR-JET-PR--6.