Published December 1999 | Version v1
Journal article

Patient doses from neuroradiological procedures

  • 1. Department of Human Services, Melbourne, VIC (Australia). Radiation Safety Unit
  • 2. The Royal Melbourne Hospital, VIC (Australia). Department of Radiology

Description

Patient doses have been determined for a sample of 20 patients in a hospital department undergoing various interventional neuroradiological procedures. Skin entrance dose, dose-area product and effective dose have been estimated. Effective dose was estimated from published conversion factors. The highest dose on the patients body was recorded as the maximum skin entrance dose. The maximum skin entrance dose varied from 0.2 to 2.3 Gy. The largest maximum skin entrance dose is similar to the threshold for skin injuries (erythema). The effective dose varied from 2 to 34 mSv. The results of this study are compared with the results of other studies on radiation dose to patients from neuroradiological procedures. Copyright (1999) Australasian Physical and Engineering Sciences in Medicine and the College of Biomedical Engineers

Additional details

Publishing Information

Journal Title
Australasian Physical and Engineering Sciences in Medicine
Journal Volume
22
Journal Issue
4
Journal Page Range
p. 153-162
ISSN
0158-9938
CODEN
AUPMDI

Optional Information

Notes
22 refs., 7 tabs.,