Published February 1987 | Version v1
Journal article

A parametric study of an anticipated transient without scram in a Westinghouse four-loop plant

  • 1. Energy Inc., One Energy Drive, Idaho Falls, ID (USA)

Description

A RETRAN-02 analysis was performed for a loss-of-feedwater transient without scram for a Westinghouse four-loop plant with Series 51 steam generators. A goal of this study was to use the same plant parameters that were used by Westinghouse in a report issued in December 1979. The primary differences in results from the two studies can be attributed to differences in the two methodologies. Sensitivity of the primary pressure response to steam generator nodalization, turbine trip time, moderator reactivity feedback coefficients, and Doppler reactivity coefficients was also studied

Additional details

Publishing Information

Journal Title
Nucl. Technol.
Journal Volume
76
Journal Issue
2
Series
Nucl. Technol.
Journal Page Range
290-302
ISSN
0029-5450
CODEN
NUTYB