Validation of Imaging With Pathology in Laryngeal Cancer: Accuracy of the Registration Methodology
Creators
- 1. Department of Radiotherapy, University Medical Center Utrecht (Netherlands)
- 2. Department of Pathology, University Medical Center Utrecht (Netherlands)
Description
Purpose: To investigate the feasibility and accuracy of an automated method to validate gross tumor volume (GTV) delineations with pathology in laryngeal and hypopharyngeal cancer. Methods and Materials: High-resolution computed tomography (CTHR), magnetic resonance imaging (MRI), and positron emission tomography (PET) scans were obtained from 10 patients before total laryngectomy. The GTV was delineated separately in each imaging modality. The laryngectomy specimen was sliced transversely in 3-mm-thick slices, and whole-mount hematoxylin-eosin stained (H and E) sections were obtained. A pathologist delineated tumor tissue in the H and E sections (GTVPATH). An automatic three-dimensional (3D) reconstruction of the specimen was performed, and the CTHR, MRI, and PET were semiautomatically and rigidly registered to the 3D specimen. The accuracy of the pathology-imaging registration and the specimen deformation and shrinkage were assessed. The tumor delineation inaccuracies were compared with the registration errors. Results: Good agreement was observed between anatomical landmarks in the 3D specimen and in the in vivo images. Limited deformations and shrinkage (3% ± 1%) were found inside the cartilage skeleton. The root mean squared error of the registration between the 3D specimen and the CT, MRI, and PET was on average 1.5, 3.0, and 3.3 mm, respectively, in the cartilage skeleton. The GTVPATH volume was 7.2 mL, on average. The GTVs based on CT, MRI, and PET generated a mean volume of 14.9, 18.3, and 9.8 mL and covered the GTVPATH by 85%, 88%, and 77%, respectively. The tumor delineation inaccuracies exceeded the registration error in all the imaging modalities. Conclusions: Validation of GTV delineations with pathology is feasible with an average overall accuracy below 3.5 mm inside the laryngeal skeleton. The tumor delineation inaccuracies were larger than the registration error. Therefore, an accurate histological validation of anatomical and functional imaging techniques for GTV delineation is possible in laryngeal cancer patients.
Availability note (English)
Available from http://dx.doi.org/10.1016/j.ijrobp.2011.05.004Additional details
Identifiers
- DOI
- 10.1016/j.ijrobp.2011.05.004;
- PII
- S0360-3016(11)00664-X;
Publishing Information
- Journal Title
- International Journal of Radiation Oncology, Biology and Physics
- Journal Volume
- 82
- Journal Issue
- 2
- Journal Page Range
- p. e289-e298
- ISSN
- 0360-3016
- CODEN
- IOBPD3
INIS
- Country of Publication
- United States
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 44016455
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ACCURACY; CARTILAGE; EOSIN; HEMATOXYLIN; IMAGES; IN VIVO; LARYNGECTOMY; NEOPLASMS; NMR IMAGING; PATHOLOGY; PATIENTS; POSITRON COMPUTED TOMOGRAPHY; RADIOTHERAPY; SHRINKAGE; SKELETON; VALIDATION
- Descriptors DEC
- ANIMAL TISSUES; AROMATICS; BODY; CARBOXYLIC ACIDS; COMPUTERIZED TOMOGRAPHY; CONNECTIVE TISSUE; DIAGNOSTIC TECHNIQUES; DISEASES; DYES; EMISSION COMPUTED TOMOGRAPHY; HETEROCYCLIC COMPOUNDS; HETEROCYCLIC OXYGEN COMPOUNDS; HYDROXY ACIDS; HYDROXY COMPOUNDS; INDICATORS; MEDICINE; NUCLEAR MEDICINE; ORGANIC ACIDS; ORGANIC BROMINE COMPOUNDS; ORGANIC COMPOUNDS; ORGANIC HALOGEN COMPOUNDS; ORGANIC OXYGEN COMPOUNDS; ORGANS; PHENOLS; POLYPHENOLS; PYRANS; RADIOLOGY; SURGERY; TESTING; THERAPY; TOMOGRAPHY
Optional Information
- Copyright
- Copyright (c) 2012 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.