Published June 2014 | Version v1
Journal article

Determination of elements in stainless steel by X-ray fluorescence spectrometry

  • 1. Nuclear Power Institute of China, Chengdu (China)

Description

Various elements in stainless steel have been measured by X-ray fluorescence spectrometry, spectral overlap and matrix effect of interference elements have been corrected by interfering. The precision and comparative tests show that the precision of the method (RSD) is less than 1% for the main portions of elements (Cr, Ni, Si, Mn, Ti, Mo, W), and the precision of the method (RSD) is less than 12% for the trace elements (Al, Cu, Co, Sn). (authors)

Additional details

Publishing Information

Journal Title
Nuclear Power Engineering
Journal Volume
35
Journal Issue
3
Journal Page Range
p. 167-169
ISSN
0258-0926

Optional Information

Notes
1 fig., 6 tabs.