Results of the motor-operated valve engineering and testing program
Creators
Description
The Texas Utilities Electric Company (TU Electric) motor-operated valve (MOV) program for implementing the recommendations of Generic Letter 89-10 has typically included the following: refurbishing each actuator, verifying each actuator's as-built configuration, testing each actuator's motor on a dynamometer, testing each actuator's torque spring pack (which is used to control the torque developed), testing each fully refurbished and reassembled actuator on a torque test stand, and testing as many MOVs as practicable both without fluid flow through the valve and with the maximum test conditions reasonably achievable (static and differential pressures (DP) conditions, respectively). Test data are acquired at 1,000 samples per second for stem thrust, stem torque, stem position, actuator compensator spring pack deflection, actuator torque spring pack deflection, motor current, motor voltage, motor three-phase power, valve upstream pressure, and valve downstream pressure, wherever practicable
Files
Additional details
Publishing Information
- Imprint Title
- Proceedings of the Third NRC/ASME Symposium on Valve and Pump Testing. Session 1A--Session 2C: Volume 1
- Imprint Pagination
- 532 p.
- Journal Page Range
- p. 101-142.
- Report number
- NUREG/CP--0137-Vol.1
Conference
- Title
- 3. ASME/NRC symposium on valve and pump testing.
- Dates
- 18-21 Jul 1994.
- Place
- Washington, DC (United States).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 26033551
- Subject category
- S22: GENERAL STUDIES OF NUCLEAR REACTORS; S42: ENGINEERING;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- DESIGN; NUCLEAR POWER PLANTS; REACTOR COMPONENTS; TESTING; VALVES
- Descriptors DEC
- CONTROL EQUIPMENT; EQUIPMENT; FLOW REGULATORS; NUCLEAR FACILITIES; POWER PLANTS; THERMAL POWER PLANTS