Published July 1994 | Version v1
Report Restricted

Results of the motor-operated valve engineering and testing program

Creators

Description

The Texas Utilities Electric Company (TU Electric) motor-operated valve (MOV) program for implementing the recommendations of Generic Letter 89-10 has typically included the following: refurbishing each actuator, verifying each actuator's as-built configuration, testing each actuator's motor on a dynamometer, testing each actuator's torque spring pack (which is used to control the torque developed), testing each fully refurbished and reassembled actuator on a torque test stand, and testing as many MOVs as practicable both without fluid flow through the valve and with the maximum test conditions reasonably achievable (static and differential pressures (DP) conditions, respectively). Test data are acquired at 1,000 samples per second for stem thrust, stem torque, stem position, actuator compensator spring pack deflection, actuator torque spring pack deflection, motor current, motor voltage, motor three-phase power, valve upstream pressure, and valve downstream pressure, wherever practicable

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Title
Proceedings of the Third NRC/ASME Symposium on Valve and Pump Testing. Session 1A--Session 2C: Volume 1
Imprint Pagination
532 p.
Journal Page Range
p. 101-142.
Report number
NUREG/CP--0137-Vol.1

Conference

Title
3. ASME/NRC symposium on valve and pump testing.
Dates
18-21 Jul 1994.
Place
Washington, DC (United States).

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
26033551
Subject category
S22: GENERAL STUDIES OF NUCLEAR REACTORS; S42: ENGINEERING;
Resource subtype / Literary indicator
Conference
Descriptors DEI
DESIGN; NUCLEAR POWER PLANTS; REACTOR COMPONENTS; TESTING; VALVES
Descriptors DEC
CONTROL EQUIPMENT; EQUIPMENT; FLOW REGULATORS; NUCLEAR FACILITIES; POWER PLANTS; THERMAL POWER PLANTS

Optional Information

Secondary number(s)
CONF-940774--Vol.1.