ATHENA calculation model for the ITER-FEAT divertor cooling system. Final report with updates

Description

An ATHENA model of the ITER-FEAT divertor cooling system has been developed for the purpose of calculating and evaluating consequences of different thermal-hydraulic accidents as specified in the Accident Analysis Specifications for the ITER-FEAT Generic Site Safety Report. The model is able to assess situations for a variety of conceivable operational transients from small flow disturbances to more critical conditions such as total blackout caused by a loss of offsite and emergency power. The main objective for analyzing this type of scenarios is to determine margins against jeopardizing the integrity of the divertor cooling system components and pipings. The model of the divertor primary heat transport system encompasses the divertor cassettes, the port limiter systems, the pressurizer, the heat exchanger and all feed and return pipes of these components. The development was pursued according to practices and procedures outlined in the ATHENA code manuals using available modelling components such as volumes, junctions, heat structures and process controls

Availability note (English)

Available from INIS in electronic form

Files

33012861.pdf

Files (660.1 kB)

Name Size Download all
md5:46a3caf4b751c98a7f4264b3ef301150
660.1 kB Preview Download

Additional details

Publishing Information

ISBN
91-7010-328-3
Imprint Pagination
47 p.
Report number
STUDSVIK-ES--01-17

Optional Information

Contract/Grant/Project number
Project no. SEA4, Task No G 81 TD 05 FE/D452
Notes
19 refs, 4 figs, 6 tabs