Published July 1, 2007 | Version v1
Report

Radiation requirements and testing of cryogenic thermometers for the ILC

Description

Large quantity of cryogenic temperature sensors will be used for operation of the International Linear Collider (ILC). Most of them will be subject to high radiation doses during the accelerator lifetime. Understanding of particle energy spectra, accumulated radiation dose in thermometers and its impact on performance are vital in establishing technical specification of cryogenic thermometry for the ILC. Realistic MARS15 computer simulations were performed to understand the ILC radiation environment. Simulation results were used to establish radiation dose requirements for commercially available cryogenic thermometers. Two types of thermometers, Cernox(regsign) and TVO, were calibrated prior to irradiation using different technique. The sensors were subjected then to up to 200 kGy electron beam irradiation with kinetic energy of 5 MeV, a representative of the situation at the ILC operation. A post-irradiation behavior of the sensors was studied. The paper describes the MARS15 model, simulation results, cryogenic test set-up, irradiation tests, and cryogenic test results

Availability note (English)

Available from http://lss.fnal.gov/cgi-bin/find_paper.pl?conf-07-355.pdf; PURL: https://www.osti.gov/servlets/purl/915549-crhOiw/

Additional details

Publishing Information

Imprint Pagination
8 p.
Report number
FERMILAB-CONF--07-355-AD

Conference

Title
Cryogenic Engineering Conference and International Cryogenic Materials Conference
Acronym
CEC-ICMC 2007
Dates
16-20 Jul 2007
Place
Chattanooga, TN (United States)

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
39104328
Subject category
S43: PARTICLE ACCELERATORS;
Resource subtype / Literary indicator
Conference, Non-conventional Literature
Descriptors DEI
COMPUTERIZED SIMULATION; CRYOGENICS; ELECTRON BEAMS; ENERGY SPECTRA; IRRADIATION; KINETIC ENERGY; LINEAR COLLIDERS; RADIATION DOSES; RADIATIONS; TESTING; THERMOMETERS
Descriptors DEC
ACCELERATORS; BEAMS; DOSES; ENERGY; LEPTON BEAMS; LINEAR ACCELERATORS; MEASURING INSTRUMENTS; PARTICLE BEAMS; SIMULATION; SPECTRA

Optional Information

Contract/Grant/Project number
AC02-76CH03000
Funding organization
US Department of Energy (United States)