Published July 1999 | Version v1
Journal article

Monitoring continuous production in a reaction pot by double detector-counts multiplication technique

  • 1. Academia Sinica, SH (China). Shanghai Inst. of Nuclear Research
  • 2. Shanghai Petrochemical Company Limitd Vinyion Factory, Shanghai (China)

Description

A new designed device for measuring the total amount of chemical stock under super criticality state is introduced. The basic principle of this device is based on the double detector-counts multiplication method. With a γ ray source placed at the middle of the reaction pot and two detectors at the top and bottom respectively, the counts from this two detectors are collected and multiplied. A self-seeking photopeak method is used to insure the system a long term stability. 238U is used as the shield material which reduces environment background obviously

Additional details

Publishing Information

Journal Title
Nuclear Electronics and Detection Technology
Journal Volume
19
Journal Issue
4
Journal Page Range
p. 256-264, 272
ISSN
0258-0934