A PIXE method for investigating the time changes of halothane content during anaesthesia

  • 1. Institute of Nuclear Physics, Krakow (Poland)
  • 2. Uniwersytet Jagiellonski, Krakow (Poland). Inst. Fizyki
  • 3. Akademia Medyczna, Krakow (Poland). Dept. of Anaesthesiology and Reanimation

Description

The PIXE method was applied to determine the time variation of the bromine in blood during and after anaesthesia. A mathematical model to describe the process responsible for the bromine distribution is proposed. (orig.)