Published September 2012
| Version v1
Journal article
Design of a simple radon surface exhalation rate measuring device
Creators
- 1. East China Institute of Technology, Nanchang (China)
- 2. Institute of Jiangxi Nuclear Industry Geological Survey, Nanchang (China)
Description
Radon and its daughters is a major contributor to natural background radiation dose, and it is a hot research topic now. In this paper, a simple radon measuring device of surface exhalation rate is designed, and it can be used to measure the radon exhalation rate of some sample surface. To understand the performance of the device, the radon exhalation rate of different samples are measured, and the measurement also verified the anti-radon effects of certain anti-radon coating. The measurement result shows that the radon surface exhalation rate of the sample can be given more accurate by the measuring device, but the measurement takes a long time. The device is of stable performance, easy to operate, but has some room to improve. (authors)
Additional details
Publishing Information
- Journal Title
- World Nuclear Geoscience
- Journal Volume
- 29
- Journal Issue
- 3
- Journal Page Range
- p. 164-167
- ISSN
- 1672-0636
INIS
- Country of Publication
- China
- Country of Input or Organization
- China
- INIS RN
- 45102448
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- BACKGROUND RADIATION; DESIGN; MEASURING INSTRUMENTS; PERFORMANCE; RADIATION DOSES; RADON
- Descriptors DEC
- DOSES; ELEMENTS; FLUIDS; GASES; NONMETALS; RADIATIONS; RARE GASES
Optional Information
- Notes
- 3 figs., 1 tabs., 10 refs.