On-line preconcentration and determination of mercury in biological and environmental samples by cold vapor-atomic absorption spectrometry
- 1. Department of Analytical Chemistry, Faculty of Chemistry, Biochemistry and Pharmacy, National University of San Luis, Chacabuco and Pedernera, P.O. Box 375, 5700 San Luis (Argentina)
- 2. Consejo Nacional de Investigaciones Cientificas y Tecnicas (CONICET), Rivadavia 1917, C1033 AAJ Buenos Aires (Argentina)
- 3. Department of Analytical Chemistry, Faculty of Chemistry, Biochemistry and Pharmacy, National University of San Luis, Chacabuco and Pedernera, P.O. Box 375, 5700 San Luis (Argentina) and Consejo Nacional de Investigaciones Cientificas y Tecnicas (CONICET), Rivadavia 1917, C1033 AAJ Buenos Aires (Argentina)
Description
An on-line procedure for the determination of traces of total mercury in environmental and biological samples is described. The present methodology combines cold vapor generation associated to atomic absorption spectrometry (CV-AAS) with preconcentration of the analyte on a minicolumn packed with activated carbon. The retained analyte was quantitatively eluted from the minicolumn with nitric acid. After that, volatile specie of mercury was generated by merging the acidified sample and sodium tetrahydroborate(III) in a continuous flow system. The gaseous analyte was subsequently introduced via a stream of Ar carrier into the atomizer device. Optimizations of both, preconcentration and mercury volatile specie generation variables were carried out using two level full factorial design (23) with 3 replicates of the central point. Considering a sample consumption of 25 mL, an enrichment factor of 13-fold was obtained. The detection limit (3σ) was 10 ng L-1 and the precision (relative standard deviation) was 3.1% (n = 10) at the 5 μg L-1 level. The calibration curve using the preconcentration system for mercury was linear with a correlation coefficient of 0.9995 at levels near the detection limit up to at least 1000 μg L-1. Satisfactory results were obtained for the analysis of mercury in tap water and hair samples
Additional details
Identifiers
- DOI
- 10.1016/j.jhazmat.2006.07.028;
- PII
- S0304-3894(06)00831-4;
Publishing Information
- Journal Title
- Journal of Hazardous Materials
- Journal Volume
- 141
- Journal Issue
- 3
- Journal Page Range
- p. 693-699
- ISSN
- 0304-3894
- CODEN
- JHMAD9
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 39018102
- Subject category
- S54: ENVIRONMENTAL SCIENCES;
- Descriptors DEI
- ABSORPTION SPECTROSCOPY; ACCURACY; ACTIVATED CARBON; CALIBRATION; DRINKING WATER; ENVIRONMENTAL MATERIALS; HAIR; MERCURY; SENSITIVITY; VAPORS; VOLATILITY; WATER POLLUTION; WATER POLLUTION CONTROL
- Descriptors DEC
- ADSORBENTS; BODY; CARBON; CONTROL; ELEMENTS; FLUIDS; GASES; HYDROGEN COMPOUNDS; MATERIALS; METALS; NONMETALS; ORGANS; OXYGEN COMPOUNDS; POLLUTION; POLLUTION CONTROL; SKIN; SPECTROSCOPY; WATER
Optional Information
- Copyright
- Copyright (c) 2006 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.