Medium-size high-temperature gas-cooled reactor
Description
This report summarizes high-temperature gas-cooled reactor (HTGR) experience for the 40-MW(e) Peach Bottom Nuclear Generating Station of Philadelphia Electric Company and the 330-MW(e) Fort St. Vrain Nuclear Generating Station of the Public Service Company of Colorado. Both reactors are graphite moderated and helium cooled, operating at approx. 7600C (14000F) and using the uranium/thorium fuel cycle. The plants have demonstrated the inherent safety characteristics, the low activation of components, and the high efficiency associated with the HTGR concept. This experience has been translated into the conceptual design of a medium-sized 1170-MW(t) HTGR for generation of 450 MW of electric power. The concept incorporates inherent HTGR safety characteristics [a multiply redundant prestressed concrete reactor vessel (PCRV), a graphite core, and an inert single-phase coolant] and engineered safety features
Availability note (English)
MF available from INIS under the Report Number; Available from NTIS., PC A03/MF A01.Files
12582256.pdf
Files
(1.9 MB)
| Name | Size | Download all |
|---|---|---|
|
md5:de9394febe88d9fed64593e5d22038f8
|
1.9 MB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- 30 p.
- Report number
- GA-A--15863
Conference
- Title
- Conference on the utilization of small and medium size power reactors in Latin America.
- Dates
- 12 - 15 May 1980.
- Place
- Montevideo, Uruguay.
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 12582256
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- HTGR TYPE REACTORS; REACTOR COMPONENTS; SPECIFICATIONS
- Descriptors DEC
- GAS COOLED REACTORS; GRAPHITE MODERATED REACTORS; REACTORS
Optional Information
- Secondary number(s)
- CONF-800578--2.