Summary of operating experience in Swiss nuclear power plants 1993
Description
In 1993 the Swiss nuclear power plants produced their third highest combined annual output. The contribution to the total electricity generation in the country was close to 37%. Replacement of the steam generators in Beznau Unit 1 resulted in a longer than usual annual outage. For the other four units the availability figures were close to, or exceeded, those of previous years. The energy utilization was, however, lowered due to load reduction in autumn resulting from unusually high production by the hydro-electric power plants. The steam generator replacement at Beznau enabled an increase in electrical power of about 2% without increase in reactor power. With the approval of the Swiss government in December 1992, the output of the Muehleberg power plant was increased in two stages by a total of 10%. The application for an unlimited operating license for Beznau Unit 2, and for a power uprate at the Leibstadt power plant, are still pending. The average number of scrams at the Swiss plants remained stable, at less than one scram per reactor year. As a result of experience in the Swedish nuclear power plant at Barsebaeck, the suction strainers of the emergency core cooling systems of the boiling water reactors at Muehleberg and Leibstadt were replaced by strainers with larger surface areas. The re-inspection of crack indications previously detected in the core shroud of the Muehleberg reactor and the penetration tubes in the reactor pressure vessel closure head of Beznau revealed no growth during the intervening operating periods. Following the completion of installation activities during the annual outages at Beznau Unit 1, Goesgen and Leibstadt, all Swiss nuclear power plants are now equipped with filtered containment venting systems. (author) figs., tabs
Availability note (English)
MF available from INIS under the Report Number.Files
25074830.pdf
Files
(405.7 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:5b8f03103f7b1fb5f7ed99d0b483611a
|
405.7 kB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- 16 p.
- Report number
- INIS-mf--14389
INIS
- Country of Publication
- Switzerland
- Country of Input or Organization
- Switzerland
- INIS RN
- 25074830
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Resource subtype / Literary indicator
- Numerical Data
- Descriptors DEI
- AVAILABILITY; BEZNAU-1 REACTOR; BEZNAU-2 REACTOR; CONTAINMENT SYSTEMS; GOESGEN REACTOR; LEIBSTADT REACTOR; MUEHLEBERG REACTOR; NUCLEAR POWER PLANTS; RADIATION DOSES; REACTOR OPERATION; SCRAM; STATISTICAL DATA; SWITZERLAND; VENTS
- Descriptors DEC
- BWR TYPE REACTORS; CONTAINMENT; DATA; DEVELOPED COUNTRIES; ENGINEERED SAFETY SYSTEMS; ENRICHED URANIUM REACTORS; EUROPE; INFORMATION; NUCLEAR FACILITIES; NUMERICAL DATA; OPERATION; POWER PLANTS; POWER REACTORS; PWR TYPE REACTORS; REACTOR SHUTDOWN; REACTORS; SHUTDOWN; THERMAL POWER PLANTS; THERMAL REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS