Published March 2008 | Version v1
Report Open

Evaluation of the Westinghouse 10B depletion for BWR control rods

Description

The aim of this work was to establish the 10B depletion model for CR 99 control rods by using the latest version of POLCA7. In order to obtain an understanding of the differences between the currently used 10B depletion models implemented in POLCA4 at O3 and in SIMULATE-3 at OL1, and the latest improved model implemented in the latest POLCA7, this work has been performed in three different parts. The first part of the work was to find out how large differences there exist in 10B depletion between the calculated data by using the latest core monitoring system (POLCA7 version 4.10.0) and the measured data obtained in the hot-cell laboratory in Studsvik. It was found that the 10B depletion computed by the latest POLCA7 version is in good agreement with the measured data from Studsvik. A poor agreement with a conservative overestimation in 10B depletion was also found between the old model and the measured data. The aim of the second part of the work was to compare the calculated 10B depletion values for two CR 99 rods from Olkiluoto 1 with the calculated 10B depletion value for a CR 99 rod from Oskarshamn 3, by using the new 10B depletion model implemented in the latest POLCA7 version. Swelling measurements of the boron carbide pins, used as absorber material, have indicated that the 10B depletion should be of similar magnitude for the rods in Olkiluoto 1 and the rod in Oskarshamn 3, whereas the calculated values by using the earlier 10B depletion models on the process computers showed a difference of about 20 %. By using the new 10B depletion model m POLCA7, it was found that the 10B depletion in the two studied cases was similar to each other and, thus, the hypothesis of a linear relationship between B4C swelling and thermal neutron fluence was supported. This third part of the work was carried out at KKL, Switzerland, and focused on comparing the B depletion models used in Westinghouse/POLCA7 and KKL/PRESTO-2. It was found that there is a slight difference in the 10B depletion, in the order of 2.5%, and suggestions to explain this behavior were given

Availability note (English)

Available from INIS in electronic form

Files

39069866.pdf

Files (16.1 MB)

Name Size Download all
md5:0077595746783dbc2b5d013cdfa393c3
16.1 MB Preview Download

Additional details

Publishing Information

Imprint Pagination
55 p.
Report number
CTH-NT--216

Optional Information

Notes
16 refs., 43 figs.