Zinc corrosion after loss-of-coolant accidents in pressurized water reactors – Physicochemical effects
Creators
- 1. Helmholtz-Zentrum Dresden-Rossendorf, Institute of Fluid Dynamics, P.O. Box 510119, D-01314 Dresden (Germany)
- 2. Hochschule Zittau/Görlitz, Institute of Process Technology, Process Automation and Measuring Technology, Theodor-Körner-Allee 16, D-02763 Zittau (Germany)
Description
Highlights: • Physicochemical effects due to post-LOCA zinc corrosion in PWR were elucidated. • Decreasing solubility of corrosion products with increasing temperature was found. • Solid corrosion products may be deposited on hot surfaces and/or within hot-spots. • Corrosion products precipitating from coolant were identified as zinc borates. • Depending on coolant temperature, different types of zinc borate are formed. - Abstract: Within the framework of the reactor safety research, generic experimental investigations were carried out aiming at the physicochemical background of possible zinc corrosion product formation, which may occur inside the reactor pressure vessel during the sump circulation operation after loss-of-coolant accidents in pressurized water reactors. The contact of the boric acid containing coolant with hot-dip galvanized steel containment internals causes corrosion of the corresponding materials resulting in dissolution of the zinc coat. A retrograde solubility of zinc corrosion products with increasing temperature was observed during batch experiments of zinc corrosion in boric acid containing coolants. Thus, the formation and deposition of solid corrosion products cannot be ruled out if the coolant containing dissolved zinc is heated up during its recirculation into hot regions within the emergency cooling circuit (e.g. hot-spots in the core). Corrosion experiments at a lab-scale test facility, which included formation of corrosion products at a single heated cladding tube, proved that dissolved zinc, formed at low temperatures in boric acid solution by zinc corrosion, turns into solid deposits of zinc borates when contacting heated zircaloy surfaces during the heating of the coolant. Moreover, the temperature of formation influences the chemical composition of the zinc borates and thus the deposition and mobilization behavior of the products
Availability note (English)
Available from http://dx.doi.org/10.1016/j.nucengdes.2014.09.010Additional details
Identifiers
- DOI
- 10.1016/j.nucengdes.2014.09.010;
- PII
- S0029-5493(14)00506-8;
Publishing Information
- Journal Title
- Nuclear Engineering and Design
- Journal Volume
- 280
- Journal Page Range
- p. 570-578
- ISSN
- 0029-5493
- CODEN
- NEDEAU
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 46100819
- Subject category
- S42: ENGINEERING;
- Descriptors DEI
- BORIC ACID; CLADDING; CONTAINMENT; COOLANTS; COOLING; CORROSION; CORROSION PRODUCTS; DISSOLUTION; HEATING; LOSS OF COOLANT; PRESSURE VESSELS; PWR TYPE REACTORS; REACTOR SAFETY
- Descriptors DEC
- ACCIDENTS; BORON COMPOUNDS; CHEMICAL REACTIONS; CONTAINERS; DEPOSITION; ENRICHED URANIUM REACTORS; HYDROGEN COMPOUNDS; INORGANIC ACIDS; INORGANIC COMPOUNDS; OXYGEN COMPOUNDS; POWER REACTORS; REACTOR ACCIDENTS; REACTORS; SAFETY; SURFACE COATING; THERMAL REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS
Optional Information
- Copyright