Published April 1990 | Version v1
Miscellaneous

Securing nuclear safety of advanced pressurized water reactors

Creators

  • 1. Ceske Vysoke Uceni Technicke, Prague (Czechoslovakia)

Description

Reliability safety assessment makes it possible to evaluate and compare the individual project variants in the stage of designing. The method is a two-stage one, of which stage one is an analysis of the existing units while stage two is an iterative process of seeking a better solution. The process is described of reliability assessment of safety in the development of the Westinghouse AP-1350 and AP-600 advanced pressurized water reactors with outputs of 1,350 and 600 MW, respectively. Emphasis is placed on passive safety systems. The safety of advanced reactors is roughly one order of magnitude higher than that of conventional pressurized water reactors. (M.D.)

Part of:
Operation and maintenance of nuclear power plant

Additional details

Additional titles

Original title (Czech)
Zajistovani jaderne bezpecnosti pokrocilych bloku s tlakovodnimi reaktory

Publishing Information

Imprint Title
Operation and maintenance of nuclear power plant
Imprint Pagination
246 p.
Journal Page Range
p. 89-96.
Report number
INIS-mf--12796

Conference

Title
Operation and maintenance of nuclear power plant.
Original Conference Title
Provozovani a udrzba jaderne elektrarny
Dates
24-26 Apr 1990.
Place
Nove Mesto na Morave (Czechoslovakia).

Optional Information

Notes
Imprint:Provozovani a udrzba jaderne elektrarny.;Sbornik prednasek celostatni konference.