Closure Report for Corrective Action Unit 224: Decon Pad and Septic Systems, Nevada Test Site, Nevada
Description
Corrective Action Unit (CAU) 224 is located in Areas 02, 03, 05, 06, 11, and 23 of the Nevada Test Site, which is situated approximately 65 miles northwest of Las Vegas, Nevada. CAU 224 is listed in the Federal Facility Agreement and Consent Order (FFACO) of 1996 as Decon Pad and Septic Systems and is comprised of the following nine Corrective Action Sites (CASs): CAS 02-04-01, Septic Tank (Buried); CAS 03-05-01, Leachfield; CAS 05-04-01, Septic Tanks (4)/Discharge Area; CAS 06-03-01, Sewage Lagoons (3); CAS 06-05-01, Leachfield; CAS 06-17-04, Decon Pad and Wastewater Catch; CAS 06-23-01, Decon Pad Discharge Piping; CAS 11-04-01, Sewage Lagoon; and CAS 23-05-02, Leachfield. The Nevada Division of Environmental Protection (NDEP)-approved corrective action alternative for CASs 02-04-01, 03-05-01, 06-03-01, 11-04-01, and 23-05-02 is no further action. As a best management practice, the septic tanks and distribution box were removed from CASs 02-04-01 and 11-04-01 and disposed of as hydrocarbon waste. The NDEP-approved correction action alternative for CASs 05-04-01, 06-05-01, 06-17-04, and 06-23-01 is clean closure. Closure activities for these CASs included removing and disposing of radiologically and pesticide-impacted soil and debris. CAU 224 was closed in accordance with the NDEP-approved CAU 224 Corrective Action Plan (CAP). The closure activities specified in the CAP were based on the recommendations presented in the CAU 224 Corrective Action Decision Document (U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office, 2005). This Closure Report documents CAU 224 closure activities. During closure activities, approximately 60 cubic yards (yd3) of mixed waste in the form of soil and debris; approximately 70 yd3 of sanitary waste in the form of soil, liquid from septic tanks, and concrete debris; approximately 10 yd3 of hazardous waste in the form of pesticide-impacted soil; approximately 0.5 yd3 of universal waste in the form of fluorescent light bulbs; and approximately 0.5 yd3 of low-level waste in the form of a radiologically impacted fire hose rack were generated, managed, and disposed of appropriately. Waste minimization techniques, such as the utilization of laboratory analysis and field screening to guide the extent of excavations, were employed during the performance of closure work
Availability note (English)
Available from INIS in electronic form; Also available from OSTI as DE00924728; PURL: https://www.osti.gov/servlets/purl/924728-7i9ot4/
Files
Additional details
Identifiers
Publishing Information
- Imprint Pagination
- 188 p.
- Report number
- DOE/NV--1234
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 39093498
- Subject category
- S12: MANAGEMENT OF RADIOACTIVE WASTES, AND NON-RADIOACTIVE WASTES FROM NUCLEAR FACILITIES;
- Descriptors DEI
- CLOSURES; CONCRETES; ENVIRONMENTAL PROTECTION; HOSES; HYDROCARBONS; LIGHT BULBS; MANAGEMENT; MINIMIZATION; NEVADA TEST SITE; ORDERS; SECURITY; SEWAGE; SOILS; TANKS; WASTES
- Descriptors DEC
- ADMINISTRATIVE PROCEDURES; BUILDING MATERIALS; CONTAINERS; MATERIALS; NATIONAL ORGANIZATIONS; NUCLEAR TEST SITES; OPTIMIZATION; ORGANIC COMPOUNDS; TUBES; US DOE; US ORGANIZATIONS; WASTES
Optional Information
- Contract/Grant/Project number
- AC52-06NA25946
- Notes
- doi 10.2172/924728
- Funding organization
- USDOE - National Nuclear Security Administration (NNSA) (United States)
- Secondary number(s)
- DOE/NV--25946-301