Published January 7, 2003 | Version v1
Journal article

Refined gypsum effective attenuation coefficients for Co-60, 6 MV, 10 MV and 18 MV x-rays

  • 1. Department of Radiation Oncology, Loyola University Chicago Stritch School of Medicine, 2160 S 1st Avenue, Maywood, IL (United States)

Description

We report new effective linear attenuation coefficients (μeff) for refined gypsum for Co-60 and 18 MV x-rays. 6 MV and 10 MV μeff agree with published data. For a 100 cm2 field size (FS), tissue defect x = 1.35 cm, target depth d = 1.65 cm beneath the tissue defect x, μeff is 0.123 cm-1 (Co-60) and 0.0934 cm-1 (6 MV). For 100 cm2, x = 1.35 cm, and d 5.65 cm beneath x, μeff is 0.072 cm-1 (10 MV), and 0.0614 cm-1 (18 MV). For d, μeff decreases about 10% from 25 to 400 cm2. For a given FS, μeff decreases with d by 3%-5% for Co-60, and 3% for 6 MV, 10 MV and 18 MV, but depends on (d - x). For d, when x is large (8 cm), depending on energy and FS, μeff is 2%-4% less than when x is small (2 cm). These data were used in a treatment-planning computer to design compensator filters for a step phantom. Compensation was to within 10% in the compensation plane (CP). Above and below CP, computer-calculated ratios of doses with and without filters were 0.75-1.13. Chamber dose ratios with and without filters were 0.75-1.12

Availability note (English)

Available online at http://stacks.iop.org/0031-9155/48/63/m30105.pdf or at the Web site for the journal Physics in Medicine and Biology (ISSN 1361-6560) http://www.iop.org/

Additional details

Identifiers

Publishing Information

Journal Title
Physics in Medicine and Biology
Journal Volume
48
Journal Issue
1
Journal Page Range
p. 63-71
ISSN
0031-9155
CODEN
PHMBA7