Patient radiation dose in some dental radiography clinics in Khartoum, Sudan
- 1. Atomic Energy Research Coordination Council, Sudan Academy of Sciences (SAS), Khartoum (Sudan)
Description
Patient dose audit is an important tool for quality control and it is important for monitoring patient exposure. The DAP meter has proved to be an easy and accurate tool for patient dosimetry and for establishment of diagnostic reference levels in dental radiology. The objective of this study was measure patient dose in dental radiography in some dental radiography clinics in Khartoum. The study was performed in five dental clinics comprising six panoramic and six intraoral dental radiography devices in Khartoum state. The incident surface air kerma (ki) and dose area product were measured for intraoral and panoramic dental examinations, respectively for digital and film imaging modalities. Incident surface air kerma (ki) was measured using calibrated dose rate meter where dose area product were determined from dose width product (DWP) measured using 3 cc pencil type CT ionization chamber. For intraoral examinations, the maximum, average and minimum, (1.95, 1.48, and 1.24) mGy, (5.84, 4.54, and 3.6) mGy for digital and imaging, respectively. This result was lower in digital in traol and higher in film imaging. The result for panoramic examination calculated dose area product (DAP) mean value for adult and pediatric was (103, 70.42) mGy cm2, respectively, where the dose for digital imaging was highest in two centers, compared to previous study. Increased patient dose in intraoral dental radiography could partially be explained by the use of circular collimators. or intraoral x-ray equipment the downward trend in patient dose can only be continue, a through the adoption of digital imaging methods. Our results are relatively higher in digital panoramic dental examinations. It is important to point out that non of the dental units under study were covered by regular quality assurance programme.(Author)
Availability note (English)
Also available From Sudan Atomic Energy Commission, Khartoum (SD)Files
47111935.pdf
Files
(21.8 MB)
| Name | Size | Download all |
|---|---|---|
|
md5:4d7942ef9790de480c7d48c94b195778
|
21.8 MB | Preview Download |
Additional details
Publishing Information
- Imprint Place
- Khartoum (Sudan)
- Imprint Pagination
- 48 p.
- Report number
- INIS-SD--626
INIS
- Country of Publication
- Sudan
- Country of Input or Organization
- Sudan
- INIS RN
- 47111935
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY; S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Resource subtype / Literary indicator
- Numerical Data, Thesis
- Descriptors DEI
- BIOMEDICAL RADIOGRAPHY; CALIBRATION; DIAGNOSIS; DOSIMETRY; IMAGES; INTERLABORATORY COMPARISONS; IONIZATION CHAMBERS; KERMA; LEVELS; MEDICAL EXAMINATIONS; MONITORING; NUMERICAL DATA; PATIENTS; QUALITY CONTROL; RADIATION DOSES; RADIOLOGY; SUDAN; SURFACE AIR
- Descriptors DEC
- AFRICA; AIR; ARAB COUNTRIES; CONTROL; DATA; DEVELOPING COUNTRIES; DIAGNOSTIC TECHNIQUES; DOSES; FLUIDS; GASES; INFORMATION; MEASURING INSTRUMENTS; MEDICAL SURVEILLANCE; MEDICINE; NUCLEAR MEDICINE; RADIATION DETECTORS; RADIOLOGY
Optional Information
- Notes
- 17 refs., 6 figs., 5 tabs.