Laboratory autoclave LAKIM-25 was created for investigation of cyclic and static crack resistance of vessel materials of power plants under the conditions close to operation ones. It enables to investigate the cyclic crack resistance of standard samples of up to 25 mm thickness in water at 623 K and 18 MPa. The friction force changes during tests from 6.1 up to 6.4 kN, therefore it is necessary to correct regularly the force of sample loading, recording the s-n diagram on a drum of UMEh-10TM plant. The periodic record of loading diagram coincides with respect to time with the necessity of controlling the change of sample pliability during crack propagation

Additional details

Additional titles

Original title (Russian)
Методические аспекты автоклавных испытаний компактных образцов на циклическую трещиностойкость

Publishing Information

Journal Title
Fiz.-Khim. Mekh. Mater.
Journal Volume
20
Journal Issue
1
Series
Fiz.-Khim. Mekh. Mater.
Journal Page Range
81-83