A systematic characterization of the low-energy photon response of plastic scintillation detectors
Creators
- 1. Département de Physique, de Génie physique et d'Optique, et Centre de recherche sur le cancer, Université Laval, Québec, QC G1V 0A6 (Canada)
- 2. Department of Radiation Physics, The University of Texas MD Anderson Cancer Center and The University of Texas Graduate School of Biomedical Sciences at Houston, Houston, TX 77003 (United States)
- 3. Standard Imaging Inc., Middleton, WI 53562 (United States)
- 4. Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin-Madison, Madison, WI, 53705 (United States)
- 5. Département de Physique, de Génie physique et d'Optique, Université Laval, Québec, QC G1V 0A6 (Canada)
Description
To characterize the low energy behavior of scintillating materials used in plastic scintillation detectors (PSDs), 3 PSDs were developed using polystyrene-based scintillating materials emitting in different wavelengths. These detectors were exposed to National Institute of Standards and Technology (NIST)-matched low-energy beams ranging from 20 kVp to 250 kVp, and to 137Cs and 60Co beams. The dose in polystyrene was compared to the dose in air measured by NIST-calibrated ionization chambers at the same location. Analysis of every beam quality spectrum was used to extract the beam parameters and the effective mass energy-absorption coefficient. Monte Carlo simulations were also performed to calculate the energy absorbed in the scintillators' volume. The scintillators' expected response was then compared to the experimental measurements and an energy-dependent correction factor was identified to account for low-energy quenching in the scintillators. The empirical Birks model was then compared to these values to verify its validity for low-energy electrons. The clear optical fiber response was below 0.2% of the scintillator's light for x-ray beams, indicating that a negligible amount of fluorescence contamination was produced. However, for higher-energy beams (137Cs and 60Co), the scintillators' response was corrected for the Cerenkov stem effect. The scintillators' response increased by a factor of approximately 4 from a 20 kVp to a 60Co beam. The decrease in sensitivity from ionization quenching reached a local minimum of about between 40 keV and 60 keV x-ray beam mean energy, but dropped by 20% for very low-energy (13 keV) beams. The Birks model may be used to fit the experimental data, but it must take into account the energy dependence of the kB quenching parameter. A detailed comprehension of intrinsic scintillator response is essential for proper calibration of PSD dosimeters for radiology. (paper)
Availability note (English)
Available from http://dx.doi.org/10.1088/0031-9155/61/15/5569Additional details
Identifiers
Publishing Information
- Journal Title
- Physics in Medicine and Biology
- Journal Volume
- 61
- Journal Issue
- 15
- Journal Page Range
- p. 5569-5586
- ISSN
- 0031-9155
- CODEN
- PHMBA7
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 51021174
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY; S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- AIR POLLUTION ABATEMENT; CALIBRATION; CESIUM 137; COBALT 60; COMPARATIVE EVALUATIONS; DOSEMETERS; EFFECTIVE MASS; ENERGY ABSORPTION; ENERGY DEPENDENCE; FLUORESCENCE; IONIZATION CHAMBERS; MONTE CARLO METHOD; PHOSPHORS; PLASTIC SCINTILLATION DETECTORS; POLYSTYRENE; QUENCHING; RADIOLOGY; VISIBLE RADIATION
- Descriptors DEC
- ABSORPTION; BETA DECAY RADIOISOTOPES; BETA-MINUS DECAY RADIOISOTOPES; CALCULATION METHODS; CESIUM ISOTOPES; COBALT ISOTOPES; ELECTROMAGNETIC RADIATION; EMISSION; EVALUATION; INTERMEDIATE MASS NUCLEI; INTERNAL CONVERSION RADIOISOTOPES; ISOMERIC TRANSITION ISOTOPES; ISOTOPES; LUMINESCENCE; MASS; MATERIALS; MEASURING INSTRUMENTS; MEDICINE; MINUTES LIVING RADIOISOTOPES; NUCLEAR MEDICINE; NUCLEI; ODD-EVEN NUCLEI; ODD-ODD NUCLEI; ORGANIC COMPOUNDS; ORGANIC POLYMERS; PETROCHEMICALS; PETROLEUM PRODUCTS; PHOTON EMISSION; PLASTICS; POLLUTION ABATEMENT; POLYMERS; POLYOLEFINS; POLYVINYLS; RADIATION DETECTORS; RADIATIONS; RADIOISOTOPES; SCINTILLATION COUNTERS; SOLID SCINTILLATION DETECTORS; SORPTION; SYNTHETIC MATERIALS; YEARS LIVING RADIOISOTOPES