Published January 27, 1977 | Version v1
Report Open

Subsurface stabilization by grouting of a simulated underground tank

Description

A moisture barrier using water, sodium silicate, formamide, calcium chloride and penechem with a gel time of one-half hour was constructed around a simulated tank 10 feet deep by 10 feet diameter in the subsurface of the 200 West Area. As a test of the moisture barrier integrity, the volume which would normally be occupied by a tank was excavated and filled with water. The barrier was unable to contain the water. The failure to achieve a water-tight barrier was attributed to a leak in the floor grout

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS., PC A03/MF A01.

Files

9380075.pdf

Files (7.0 MB)

Name Size Download all
md5:feb71156f2bbf91707c892753b694b30
7.0 MB Preview Download

Additional details

Publishing Information

Imprint Pagination
34 p.
Report number
ARH-CD--877