Published June 1982 | Version v1
Report Open

Wall conditioning of the JIPP T-II TORUS by AC discharge cleaning

Description

Optimization of discharge cleaning was studied by using 60 Hz AC and cw ECR discharges. Reduction rate of oxygen was investigated for variations of the wall temperature. It has been confirmed that, below 3000C, the reduction rate increases as the wall temperature is raised. A simple model is proposed for the cleaning process and H2O pressure is calculated as a function of plasma density on the basis of this model. By comparing the calculated results to an experimental observation, it has been found that it is essential to raise the electron density of the discharge-cleaning plasma high enough that the dissociation-loss rate of H2O is as large as the sticking-loss rate in order to optimize the cleaning. (author)

Availability note (English)

MF available from INIS under the Report Number.

Files

14803787.pdf

Files (162.4 kB)

Name Size Download all
md5:d78c9f582cfbdca5e80a5013a79f0b61
162.4 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
14 p.
Report number
IPPJ--595