Published November 2000 | Version v1
Journal article

A comparison of normalization effects on three whole-body cylindrical 3D PET systems

  • 1. Division of Nuclear Medicine, University of Washington, Seattle, WA 98195 (United States).
  • 2. Division of Nuclear Medicine, Dana Farber Cancer Institute and Harvard Medical School, 44 Binney Street, Boston, MA 02115 (United States)
  • 3. Servico de Biofisica, Faculdade de Medicina da Universidade de Coimbra, 3000 Coimbra (Portugal)
  • 4. Service Hospitalier Frederic Joliot, 4, Place du General Leclerc, 91406 Orsay (France)
  • 5. Division of Nuclear Medicine, University of Washington, Seattle, WA 98195 (United States)
  • 6. Department of Molecular and Medical Pharmacology, Division of Nuclear Medicine, UCLA School of Medicine, Los Angeles, CA 90095 (United States)
  • 7. Guy's and St Thomas' Clinical PET Centre, Division of Radiological Sciences and Medical Engineering, King's College, London (United Kingdom)

Description

Normalization coefficients in three-dimensional positron emission tomography (3D PET) are affected by parameters such as camera geometry and the design and arrangement of the block detectors. In this work, normalization components for three whole-body 3D-capable tomographs (the GE Advance, the Siemens/CTI 962/HR+ and the Siemens/CTI 951R) are compared by means of a series of scans using uniform cylindrical and rotating line sources. Where applicable, the manufacturers' normalization methods are validated, and it is shown that these methods can be improved upon by using previously published normalization protocols. Those architectural differences between the three tomographs that affect normalization are discussed with a view to drawing more general conclusions about the effect of machine architecture on normalization. The data presented suggest that uniformity of system response becomes easier to achieve as the uniformity of crystal response within the detector block is improved. (author)

Availability note (English)

Available online at the Web site for the journal Physics in Medicine and Biology (ISSN 1361-6560) http://www.iop.org/

Additional details

Identifiers

Publishing Information

Journal Title
Physics in Medicine and Biology
Journal Volume
45
Journal Issue
11
Journal Page Range
p. 3253-3266
ISSN
0031-9155
CODEN
PHMBA7

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
43119813
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
CORRECTIONS; DETECTION; DIAGNOSTIC USES; GEOMETRY; POSITRON COMPUTED TOMOGRAPHY; THREE-DIMENSIONAL CALCULATIONS
Descriptors DEC
COMPUTERIZED TOMOGRAPHY; DIAGNOSTIC TECHNIQUES; EMISSION COMPUTED TOMOGRAPHY; MATHEMATICS; TOMOGRAPHY; USES

Optional Information

Notes
Refs; This record replaces 31063652