Estimation of cardiac CT angiography radiation dose toward the establishment of national diagnostic reference level for CCTA in Iran
Creators
- 1. Cellular and Molecular Biology Research Center, Babol University of Medical Sciences, Babol (Iran, Islamic Republic of)
- 2. Department of Medical Physics, Radiobiology and Radiation Protection, Faculty of Medicine, Babol University of Medical Sciences, Babol (Iran, Islamic Republic of)
- 3. Department of Medical Physics, School of Medicine, Shahid Beheshti University of Medical Sciences, Tehran (Iran, Islamic Republic of)
- 4. Department of Medical Physics, Iran University of Medical Sciences, Tehran (Iran, Islamic Republic of)
- 5. Department of Radiology, Babol University of Medical Sciences, Babol (Iran, Islamic Republic of)
Description
In recent years, with the introduction of 64-slice CT and dual-source CT technology, coronary CT angiography (CCTA) has emerged as a useful diagnostic imaging modality as a non-invasive assessment of coronary heart disease. CT produces a larger radiation dose than other imaging tests and cardiac CT involves higher radiation dose with the advances in the spatial and temporal resolution. The aims of this study are patient dose assessment and establishment of national diagnostic reference level for CCTA in Iran. A questionnaire was sent to CCTA centers. Data for patient and CT protocols were obtained. The volumetric CT dose index (CTDIvol), dose length product (DLP) and total DLP were considered in the 32 cm standard body phantom. Calculation of estimated effective dose (ED) was obtained by multiplying the DLP by a conversion factor [k = 0.014 mSv (mGy.cm)-1 ]. Mean value of CTDIvol and DLP for CCTA was 50 mGy and 825 mGy.cm. The third quartile (75.) of the distribution of mean CTDI-v-o-l (66.54 mGy) and DLP (1073 mGy.cm) values was expressed as the diagnostic reference level (DRL) for CCTA in Iran. The median of ED was 10.26 mSv and inter-quartile range of ED was 7.08-15.03 mSv. A large variety in CTDIvol and DLP among CT scanner and different sites due to variability in CT parameter is noted. It seems that training could help to reduce patient's dose. (authors)
Availability note (English)
Available from doi: http://dx.doi.org/10.1093/rpd/ncw249Additional details
Identifiers
- DOI
- 10.1093/rpd/ncw249;
Publishing Information
- Journal Title
- Radiation Protection Dosimetry
- Journal Volume
- 174
- Journal Issue
- 4
- Journal Page Range
- p. 551-557
- ISSN
- 0144-8420
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- France
- INIS RN
- 48063662
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY; S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- BIOMEDICAL RADIOGRAPHY; CARDIOVASCULAR DISEASES; COMPUTERIZED TOMOGRAPHY; CORONARIES; HEART; IRAN; PATIENTS; PHANTOMS; RADIATION DOSES
- Descriptors DEC
- ARTERIES; ASIA; BLOOD VESSELS; BODY; CARDIOVASCULAR SYSTEM; DEVELOPING COUNTRIES; DIAGNOSTIC TECHNIQUES; DISEASES; DOSES; MEDICINE; MIDDLE EAST; MOCKUP; NUCLEAR MEDICINE; ORGANS; RADIOLOGY; STRUCTURAL MODELS; TOMOGRAPHY
Optional Information
- Notes
- 21 refs.