Published May 1990
| Version v1
Journal article
A Study on Comparison of Acoustic Emission, Ultrasonic Testing and Crack Gauge Method in 3-point Bending Testing
Creators
- 1. Hanyang University, Seoul (Korea, Republic of)
- 2. Chosun University, Gwangju (Korea, Republic of)
Description
Comparison of acoustic emission, ultrasonic testing and crack gauge in 3-point bending testing have been studied. As the results, COD is indirectly assumed by strain gauge rate and grid pitch width when crack gauge grid is out. Acoustic emission is qualitatively able to measure crack growth by total count but ultrasonic testing has a difficulty in measuring it because of echo height fluctuation according to the change and pressure of UT. probe
Additional details
Publishing Information
- Journal Title
- Journal of the Korean Society for Nondestructive Testing
- Journal Volume
- 10
- Journal Issue
- 1
- Series
- 10 refs, 16 figs, 1 tab
- Journal Page Range
- p. 65-72
- ISSN
- 1225-7842
INIS
- Country of Publication
- Korea, Republic of
- Country of Input or Organization
- Korea, Republic of
- INIS RN
- 42102742
- Subject category
- S42: ENGINEERING;
- Descriptors DEI
- ACOUSTIC EMISSION TESTING; BENDING; CRACKS; STRAINS; ULTRASONIC TESTING
- Descriptors DEC
- ACOUSTIC TESTING; DEFORMATION; MATERIALS TESTING; NONDESTRUCTIVE TESTING; TESTING