Evaluation of Positioning Accuracy of Four Different Immobilizations Using Cone-Beam CT in Radiotherapy of Non-Small-Cell Lung Cancer

  • 1. Division of Thoracic Tumor, Cancer Center, West China Hospital, Sichuan University, Chengdu (China)
  • 2. Division of Radiation Physics, Cancer Center, West China Hospital, Sichuan University, Chengdu (China)
  • 3. Division of Abdominal Tumour, Cancer Center, West China Hospital, Sichuan University, Chengdu (China)

Description

Purpose: To evaluate the positioning accuracy of four different immobilizations by use of cone-beam computed tomography guidance for radiotherapy of non-small-cell lung cancer (NSCLC). Methods and Materials: Sixty-seven patients with NSCLC received conventional or stereotactic body radiotherapy. Of these, 30 were immobilized with a thermoplastic frame (TF), 16 with a thermoplastic frame and active breathing control (TF-ABC), 7 with a stereotactic body frame (SBF), and 14 with a stereotactic body frame and active breathing control (SBF-ABC). Cone-beam computed tomography scans at initial setup and after correction were registered to planning computed tomography. The positional errors in the left-to-right, superior-inferior, and anterior-posterior directions were analyzed. The planning target volume margins were calculated. Results: The precorrection systematic and random errors ranged from 1.9 to 4.2 mm for TF, 1.9 to 4.3 mm for SBF, 1.2 to 5.8 mm for TF-ABC, and 2.3 to 3.9 mm for SBF-ABC. The postcorrection systematic and random errors ranged from 0.3 to 1.9 mm for the four immobilizations. The planning target volume margins (conventional vs. stereotactic body radiotherapy) were 15.6 vs. 13.9 mm (TF), 14.9 vs. 14.8 mm (TF-ABC), 14.4 vs. 13.4 mm (SBF), and 9.9 vs. 9.4 mm (SBF-ABC) before correction and 7.3 vs. 6.9 mm (TF), 4.0 vs. 3.8 mm (TF-ABC), 7.5 vs. 7.1 mm (SBF), and 4.5 vs. 4.2 mm (SBF-ABC) after correction. Conclusions: The positioning accuracies of SBF and TF were similar. Active breathing control increased positioning error but reduced internal margin. Cone-beam computed tomography online correction improved the positioning accuracy of NSCLC patients.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.ijrobp.2009.09.049

Additional details

Identifiers

DOI
10.1016/j.ijrobp.2009.09.049;
PII
S0360-3016(09)03327-6;

Publishing Information

Journal Title
International Journal of Radiation Oncology, Biology and Physics
Journal Volume
77
Journal Issue
4
Journal Page Range
p. 1274-1281
ISSN
0360-3016
CODEN
IOBPD3

INIS

Country of Publication
United States
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
42031618
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
ACCURACY; COMPUTERIZED TOMOGRAPHY; EVALUATION; LUNGS; NEOPLASMS; POSITIONING; RADIOTHERAPY
Descriptors DEC
BODY; DIAGNOSTIC TECHNIQUES; DISEASES; MEDICINE; NUCLEAR MEDICINE; ORGANS; RADIOLOGY; RESPIRATORY SYSTEM; THERAPY; TOMOGRAPHY

Optional Information

Copyright
Copyright (c) 2010 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.