Published January 2001 | Version v1
Journal article

Measurement of radon and thoron progenies in Coimbatore

  • 1. Department of Physics, Bharathiar University, Coimbatore (India)
  • 2. Health and Safety Division, Indira Gandhi Centre for Atomic Research, Kalpakkam (India)

Description

The radon and thoron daughter concentrations have been measured in different dwellings of Coimbatore city by grab sampling method and two count. It has been found that the radon daughter concentration varies from 0.5 to 10.5 mWL with mean value of 2.9 mWL and that of thoron progeny is from 0.7 to 16.3 mWL with mean value of 3.8 mWL. The average annual effective dose equivalent due to radon daughters is found to be 1.3 mSv and that of thoron progeny is 3.8 mSv. (author)

Additional details

Publishing Information

Journal Title
Radiation Protection and Environment
Journal Volume
24
Journal Issue
1-2
Journal Page Range
p. 396-400
ISSN
0972-0464

Conference

Title
25. international conference on radiation protection measurements and dosimetry: current practices and future trends
Acronym
IARP-IC.2K1
Dates
20-23 Feb 2001
Place
Mumbai (India)

Optional Information

Notes
16 refs., 1 fig., 3 tabs.