Published 1989 | Version v1
Miscellaneous

Void fraction and pressure drop in subcooled forced convective boiling with refrigerant 12

  • 1. Technische Univ. Muenchen (Germany, F.R.). Lehrstuhl A fuer Thermodynamik

Description

This paper presents investigations and results of void fraction and pressure drop of dichlordifluormethan (CCl2F2) in forced convective subcooled boiling. The data was taken at different heat fluxes in a 12 to 25 bar pressure range, the mass fluxes have been varied from 500 to 3000 kg/m2s with an inlet subcooling in the range from 10 to 50 K. The experiments have been conducted in an annular test channel, with an 0.016 m inner diameter and 0.03 m outer diameter. The inner tube of the annulus was heated by direct current. The void fraction data was gaged with a γ-densitometer and a specially designed impedance void meter. The experimental results reveal that the void fraction is nearly constant from the onset of nucleation boiling to a subcooling of about Δ=10 K. The pressure drop shows a similar behaviour

Part of:
Thermal non equilibrium in two phase flow

Additional details

Publishing Information

Imprint Title
Thermal non equilibrium in two phase flow
Imprint Pagination
553 p.
Journal Page Range
p. 83-97.
Report number
INIS-mf--11484

Conference

Title
7. Eurotherm seminar.
Dates
23-24 Mar 1989.
Place
Rome (Italy).

INIS

Country of Publication
Italy
Country of Input or Organization
Italy
INIS RN
20060558
Subject category
S42: ENGINEERING;
Resource subtype / Literary indicator
Conference
Descriptors DEI
FORCED CONVECTION; FREONS; HEAT FLUX; PRESSURE DROP; SUBCOOLED BOILING; VOID FRACTION
Descriptors DEC
BOILING; CONVECTION; ENERGY TRANSFER; HEAT TRANSFER; ORGANIC COMPOUNDS; ORGANIC HALOGEN COMPOUNDS; PHASE TRANSFORMATIONS