Published August 1992
| Version v1
Journal article
Steady state thermal-hydraulic calculation and analysis for 5 MW low power reactor
Description
The steady state thermal-hydraulic calculation and safe margin analysis for 5 MW Low Power Reactor are described. Calculated results of pressure drop and flow distribution in the reactor core, maximum temperature of hot-channel wall, statistic analysis of hot-channel and hot-spot factors, minimum departure from nucleate boiling ratio are given. Calculation results show that this reactor possesses enough margin
Additional details
Publishing Information
- Journal Title
- Nuclear Power Engineering
- Journal Volume
- 13
- Journal Issue
- 4
- Journal Page Range
- p. 12-17.
- ISSN
- 0258-0926
- CODEN
- HDGOE6
INIS
- Country of Publication
- China
- Country of Input or Organization
- China
- INIS RN
- 24075439
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS; S22: GENERAL STUDIES OF NUCLEAR REACTORS;
- Descriptors DEI
- ALGORITHMS; CHINA; DEPARTURE NUCLEATE BOILING; EXPERIMENTAL REACTORS; HEAT FLUX; HEAT TRANSFER; HOT SPOT FACTOR; HYDRAULICS; POOL TYPE REACTORS; SAFETY ANALYSIS
- Descriptors DEC