Published August 1992 | Version v1
Journal article

Steady state thermal-hydraulic calculation and analysis for 5 MW low power reactor

  • 1. Nuclear Power Inst. of China, Chengdu, SC (China)

Description

The steady state thermal-hydraulic calculation and safe margin analysis for 5 MW Low Power Reactor are described. Calculated results of pressure drop and flow distribution in the reactor core, maximum temperature of hot-channel wall, statistic analysis of hot-channel and hot-spot factors, minimum departure from nucleate boiling ratio are given. Calculation results show that this reactor possesses enough margin

Additional details

Publishing Information

Journal Title
Nuclear Power Engineering
Journal Volume
13
Journal Issue
4
Journal Page Range
p. 12-17.
ISSN
0258-0926
CODEN